Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
01295 | TEXAS INSTRUMENTS INCORPORATED DBA T |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAV | OVERALL DIAMETER | 0.340 INCHES MINIMUM AND 0.360 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.340 INCHES MINIMUM AND 0.360 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 141.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 54.0 |
STYL | STYLE DESIGNATOR | BEAD IN CAN |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AEHX | MAXIMUM POWER DISSIPATION RATING | 0.125 WATTS |
ADAQ | BODY LENGTH | 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 376.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
ABJT | TERMINAL LENGTH | 1.438 INCHES MINIMUM AND 1.562 INCHES MAXIMUM |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 282.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
CQWD | ZERO POWER RESISTANCE | 470.000 OHMS |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
ABDN | TERMINAL SURFACE TREATMENT | TIN |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
AEBT | TERMINAL DIAMETER | 0.016 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/+15.0 ALL RESISTANCE-TEMPERATURE POINTS |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 185.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |