Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
96214 | RAYTHEON COMPANY |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 830.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 830.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ADAR | BODY OUTSIDE DIAMETER | 0.105 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
ADAQ | BODY LENGTH | 0.300 INCHES MAXIMUM |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 715.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
TEST | TEST DATA DOCUMENT | 13973-860060-7 DRAWING |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 25.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEBT | TERMINAL DIAMETER | 0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
STYL | STYLE DESIGNATOR | ROD |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 60.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.0 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AEHX | MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 600.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
CQWD | ZERO POWER RESISTANCE | 500.000 OHMS |
ABDN | TERMINAL SURFACE TREATMENT | TIN |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 955.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 420.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
ABJT | TERMINAL LENGTH | 1.200 INCHES MINIMUM |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |