Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
91196 NORTH ERIE ELECTRONICS INC DBA FISHE

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAQ BODY LENGTH 3.687 INCHES NOMINAL
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 500.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
AEHZ MAXIMUM OPERATING TEMP 400.0 DEG FAHRENHEIT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 13 SOLDER STUD
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 270.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
ADAU BODY HEIGHT 1.937 INCHES NOMINAL
AKNA INCLOSURE TYPE HERMETICALLY SEALED
ADAT BODY WIDTH 3.125 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 208.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 0.075 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 21.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 6.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 203.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP

Similar Parts

TP971 , TP971 , 5950-00-812-9055 , 5950008129055 , 008129055