Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
FEAT | SPECIAL FEATURES | PAINT ALUMINUM TT-P-320 ON ARMOR |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B355 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.543 INCHES NOMINAL |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 22 ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B3 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 14 AWG ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TRIPLES |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 3 |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATT | MATERIAL | ALUMINUM ALLOY 5056 2ND POSITION JACKET CABLE AND ALUMINUM ALLOY 6253 2ND POSITION JACKET CABLE |
SFTT | SURFACE TREATMENT | NICKEL CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | GLASS FIBER 2ND POSITION BRAID, NON-METALLIC ALL CONDUCTORS AND FIBER SYNTHETIC 2ND POSITION BRAID, NON-METALLIC ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-Y-1140 MIL SPEC ALL MATERIAL RESPONSES 2ND POSITION BRAID, NON-METALLIC ALL CONDUCTORS |
MATT | MATERIAL | RUBBER SILICONE CLASS Q 1ST POSITION JACKET CABLE |
MATT | MATERIAL | RUBBER SILICONE CLASS Q 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-C-915,ALCLAD ALLOY 5056 MIL SPEC SINGLE MATERIAL RESPONSE 2ND POSITION JACKET CABLE |