Part Number
Definition:
A VALVE HAVING TWO OR MORE PORTS WITH VALVE STEM OR PILOT NEEDLE IN A NORMALLY OPEN OR CLOSED POSITION. IT IS SPECIFICALLY DESIGNED TO STOP OR START OR CHANGE THE FLOW OF FLUID BY MEANS OF THE MAGNETIC ACTION OF AN ELECTRIC COIL ON A MOVEABLE CORE OR PLUNGER. THE VALVE MAY BE EQUIPPED WITH A MANUAL OPENING OR CLOSING DEVICE. FOR ITEMS WITH THREE OR MORE PORTS THAT UTILIZE A RECIPROCATING SLIDE WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, SEE VALVE (1), LINEAR, DIRECTIONAL CONTROL. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES VALVE (1), BUTTERFLY.
CAGE Information
Code | Company |
---|---|
81978 | PARKER-HANNIFIN CORPORATION DBA FLUI |
Federal Supply Class
Title
VALVES, POWERED
Inclusions:
INCLUDES ELECTRIC MOTOR OPERATED VALVES; HYDRAULIC OPERATED VALVES; SOLENOID OPERATED VALVES.
Exclusions:
EXCLUDES ENGINE INTAKE AND EXHAUST VALVES (FSC 2990, 2815); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AWLS | CONNECTION TYPE | UNTHREADED INTERNAL TUBE 1ST END |
AWLS | CONNECTION TYPE | UNTHREADED INTERNAL TUBE 1ST END |
FREQ | FREQUENCY IN HERTZ | 60.0 |
CWFD | NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED | 0.250 INCHES 1ST END |
AAJF | THREAD DIRECTION | RIGHT-HAND 3RD END |
AQLR | VALVE OPERATION METHOD | SOLENOID |
AHNC | CONNECTION STYLE | SOCKET (TUBE) 1ST END |
BBJX | MOUNTING POSITION | HORIZONTAL OR VERTICAL |
AWLS | CONNECTION TYPE | THREADED INTERNAL PIPE 2ND END |
ADQU | FLOW CONTROL DEVICE | DISK |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES 2ND END |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 120.0 AC |
ADSK | FLOW CONTROL DEVICE NORMAL OPERATION POSITION | CLOSED |
STYL | STYLE DESIGNATOR | ERR-090 |
AWLS | CONNECTION TYPE | THREADED INTERNAL PIPE 3RD END |
MATT | MATERIAL | STEEL CORROSION RESISTING BODY |
AHNC | CONNECTION STYLE | ERR-090 2ND END |
AMPS | CURRENT RATING IN AMPS | 0.083 |
AHNC | CONNECTION STYLE | ERR-090 3RD END |
CQGM | MAXIMUM OPERATING PRESSURE | 50.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
MEDA | MEDIA FOR WHICH DESIGNED | WATER-OIL-GAS SINGLE RESPONSE |
AAJF | THREAD DIRECTION | RIGHT-HAND 2ND END |
THSD | THREAD SERIES DESIGNATOR | NPT ALL ENDS |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES 3RD END |
FAAZ | PHASE | SINGLE |
MATT | MATERIAL | RUBBER SYNTHETIC FLOW CONTROL DEVICE |