TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
08715 CEN ELECTRONICS A DIV OF CHLORIDE PO

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACZB FREQUENCY RATING 5.0 KILOHERTZ NOMINAL SINGLE COMPONENT
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CBME CUBIC MEASURE (NON-CORE) 1.8 CUBIC INCHES
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 4.000 OUNCES
CRBZ WINDING OPERATING CURRENT 885.0 MILLIAMPERES NOMINAL B AND BETTER SINGLE COMPONENT 3RD SECONDARY AND 915.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 4.45 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 4.74 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 4TH SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
AEHZ MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
TTQY TERMINAL TYPE AND QUANTITY 12 WIRE HOOK
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 87.31 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 96.51 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY
ADAU BODY HEIGHT 1.125 INCHES MAXIMUM
AKNA INCLOSURE TYPE HERMETICALLY SEALED WITH OIL
CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 24.00 DC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 30.00 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 108.0 MILLIAMPERES NOMINAL B AND BETTER SINGLE COMPONENT 1ST SECONDARY AND 112.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
ADAT BODY WIDTH 1.280 INCHES MAXIMUM
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
FEAT SPECIAL FEATURES SECONDARY NUMBER 4 IS NOT RATED
ADAQ BODY LENGTH 1.280 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 8.48 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 12.02 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 3.5 MILLIAMPERES NOMINAL B AND BETTER SINGLE COMPONENT 2ND SECONDARY AND 3.7 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT

Similar Parts