Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code |
Company |
08715 |
CEN ELECTRONICS A DIV OF CHLORIDE PO |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CRBZ |
WINDING OPERATING CURRENT |
4.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
CRBZ |
WINDING OPERATING CURRENT |
4.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
ADAQ |
BODY LENGTH |
1.688 INCHES NOMINAL |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU |
BODY HEIGHT |
1.812 INCHES NOMINAL |
AXGY |
MOUNTING METHOD |
FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE HOOK |
CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ABTB |
MOUNTING HOLE DIAMETER |
0.169 INCHES NOMINAL SINGLE GROUP |
ADAT |
BODY WIDTH |
1.688 INCHES NOMINAL |
CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |