Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
15634 | MAGNETIKA INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 24 TAB, SOLDER LUG |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 24.50 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 24.50 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 24.50 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | I1PRIMARY,7 SECONDARY WINDINGS; ALL CURRENTS ARE SHOWN AS RECTIFIED; SECONDARIES 6 AND 7 ARE RATED THE SAME,0.1 AMP DC AT 16.5 AND 19.5 VOLTS RMS; 5TH SECONDARY IS 0.57 AMPS AT 21.50 AND 24.50 VOLTS RMS |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 4TH SECONDARY AND 24.50 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 4TH SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 2.250 POUNDS |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
CBME | CUBIC MEASURE (NON-CORE) | 16.3 CUBIC INCHES |
CWJS | WINDING OPERATING VOLTAGE | 184.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 216.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM SINGLE GROUP AND 0.165 INCHES MAXIMUM SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.1 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 3.630 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.750 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |