Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
15634 | MAGNETIKA INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/NEUTRAL TAP SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND WYE-WYE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
TEST | TEST DATA DOCUMENT | 07187-4010238 DRAWING |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND 1ST GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 1.700 POUNDS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.530 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.420 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD |
FEAT | SPECIAL FEATURES | VOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER AND COLOR CODED LEAD |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 201.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST GROUP |
CWJS | WINDING OPERATING VOLTAGE | 74.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM 2ND GROUP AND 0.165 INCHES MAXIMUM 2ND GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AAJD | THREAD CLASS (NON-CORE) | 2B 1ST GROUP |
CRBZ | WINDING OPERATING CURRENT | 230.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |