Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
77857 | ROBERTSHAW CONTROLS CO NEW STANTON D |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
AEVT | CAPILLARY TUBE LENGTH | 48.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.094 INCHES NOMINAL |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
AEVU | BULB LENGTH | 8.813 INCHES NOMINAL |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL SECOND VOLTAGE |
ADAU | BODY HEIGHT | 1.156 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 25.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT POINTER WITH SCALE AND EXTERNAL ACTUATION POINT POINTER WITH SCALE |
CTHF | CONTACT LOAD CURRENT RATING | 35.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | RECTANGULAR |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE PROOF |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.281 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
AEVV | BULB DIAMETER | 0.250 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | MANUAL RESET BUTTON |
CBBL | FEATURES PROVIDED | TUBING END SEAL CONNECTION |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +100.00/+200.00 ACTUATION POINT DEGREES FAHRENHEIT AND +100.00/+200.00 DEACTUATION POINT DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
ABHP | OVERALL LENGTH | 3.906 INCHES NOMINAL |
CSCF | TERMINAL TYPE | TAB W/SCREW |